Hi,
Since around 14:00 2024-04-01 all our MODIS Aqua L1B processing fails with error message (in LogReport):
TDLUT_ReadPeicewiseLinearFunction():MODIS_F_NOK:295817224
LUT associated with “m1” has times out of order.
As far as I can tell the LUTs were last updated at the end of October 2023 (to MYD02 LUTs V6.2.1.90_OC_v2.14) and this has been running fine until 3 days ago. There have been no code updates for a couple of years.
I saw a recent post from Karen North on the DRL users list describing what might be a similar problem with the IPOPP SPA, suggesting they were keeping LUTs back to a version from late 2022 – we run L1 processing components from SeaDAS/OCSSW but I understood them to be basically the same.
Anybody got any pointers here – or similar experience?
Thanks
Simon
Since around 14:00 2024-04-01 all our MODIS Aqua L1B processing fails with error message (in LogReport):
TDLUT_ReadPeicewiseLinearFunction():MODIS_F_NOK:295817224
LUT associated with “m1” has times out of order.
As far as I can tell the LUTs were last updated at the end of October 2023 (to MYD02 LUTs V6.2.1.90_OC_v2.14) and this has been running fine until 3 days ago. There have been no code updates for a couple of years.
I saw a recent post from Karen North on the DRL users list describing what might be a similar problem with the IPOPP SPA, suggesting they were keeping LUTs back to a version from late 2022 – we run L1 processing components from SeaDAS/OCSSW but I understood them to be basically the same.
Anybody got any pointers here – or similar experience?
Thanks
Simon
Statistics: Posted by slwood — Wed Apr 03, 2024 10:46 pm America/New_York